PRODUCT
COMPARISON
OUTDOOR LCD DIGITAL SIGNS
imotion
imotionG6 46 P FS

G6

imotionFLOW 46 P FS

FLOW

imotionLITE 46 P FS

LITE

PRODUCT
COMPARISON
OUTDOOR E-PAPER
imotion
imotionINK

INK

Description

Unique outdoor digital sign technology with most comprehensive thermal management on the market. These IP66 enclosed systems are based on advanced silent HVAC , can create “laboratory like environment” and hold perfect inner enclosure temperatures between 20-25⁰C Due to its closed airflow loop no dust particles are entering (no filters). Such set-up allow electronics to work with its full capacity, while being only minimally (naturally) degraded by heat (e.g. LED backlight luminance can drop very fast in higher temps – both instant luminance output and luminance output trough time.)

A product line, made for direct sun exposed areas in temperature range between -25 and 40⁰C, based on IP56 ventilation thermal system and high on-surface LCD panels (110⁰C). These units guarantee that all electronics operate within warranted conditions, therefore temperatures in enclosure never exceedes 50⁰C.

A semi-outdoor product line is intended for NON direct sun exposed places, such as metro stations and roof covered areas. these signs will never allow higher temperatures than 50⁰C within enclosure, in this way protecting electronics and LCD panel from working out of warranted area.

Description

imotionINK is complete electronic paper solution for outdoor use. It includes hardware and software for content management and remote diagnostics. This reflective bistable low consumption medium is ideal for simple info messaging. Electronic paper main advantage over LCD technology is in its minimal power consumption and easy of deployment.

INTENDED LOCATIONS

Sun exposed – full outdoor lcd

Sun exposed – full outdoor lcd

No sun exposure – semi outdoor lcd

INTENDED LOCATIONS

Sun exposed – full outdoor

OPERATING AMBIENT TEMP.

-40 to +55 °C

-25 to +40 °C

-20 to +40 °C

OPERATING AMBIENT TEMP.

-20°C or 0°C to 50°C

COOLING

Advanced silent HVAC – closed airflow loop

Ventilation

Ventilation

COOLING

Passive

AIRFLOW LOOP

Closed

Open

Open

AIRFLOW LOOP

Closed

ELECTRONICS COMPARTMENT ENCLOSURE RATING

IP66

IP56

IP50

ELECTRONICS COMPARTMENT ENCLOSURE RATING

IP66

INNER ENCLOSURE TEMP.

20-25 °C (unique trait!)

10-50 °C

10-50 °C

INNER ENCLOSURE TEMP.

INNER ENCLOSURE TEMP. DYNAMICS

Guaranties ideal operation condition

Guaranties ideal operation condition

Guaranties ideal operation condition

INNER ENCLOSURE TEMP. DYNAMICS

Guaranties ideal operation condition

LED BACKLIGHT LIFETIME & LUMINANCE OUTPUT

Ambient temperature (°C) effect on LED life time
Ambient temperature (°C) effect on LED life time
Ambient temperature (°C) effect on LED life time

/

NOINFORMATIONYET

LUMINANCE OUTPUT

100-110% of specified LCD panel value

Up to 100% of specified LCD panel value

Up to 100% of specified LCD panel value

LUMINANCE OUTPUT

No illumination

LED BACKLIGHT LIFETIME

70.000h

50.000h

50.000h

/

OPERATING HUMIDITY

0-100% (immunity)

10-90%

10-90%

OPERATING HUMIDITY

10-90%

DUST PARTICLES

No filter (immunity)

Filter

Filter

DUST PARTICLES

No filter (immunity)

SERVICING

No regular maintenance (automatic on-site call)

Once a year regular maintenance

Once a year regular maintenance

SERVICING

No regular maintenance

AUTOMATIC MAINTENANCE CALL

Yes

Yes

No

AUTOMATIC MAINTENANCE CALL

Yes

ELECTRONIC CONTROL UNIT

Critical, error, daily report

Critical, error, daily report

No

ELECTRONIC CONTROL UNIT

Yes

ELECTRONIC CONTROL UNIT

Fully programmable ECU tailored to achieve optimal working conditions and superior intelligence of the system

Configurable ECU

No

ELECTRONIC CONTROL UNIT

REMOTE SYSTEM HEALTH MONITORING

Yes

Yes

No

REMOTE SYSTEM HEALTH MONITORING

Yes

HIGH/LOW TEMPERATURE PROTECTION

Yes/Yes

Yes/Yes

Yes/Yes

HIGH/LOW TEMPERATURE PROTECTION

Yes/Yes

EMERGENCY SHUTDOWN

Yes

Yes

Yes

EMERGENCY SHUTDOWN

HOT/COLD SEQUENTIAL STARTUP

Between -40 and +55 °C

Between -25 and +40 °C

Between -20 and +40 °C

HOT/COLD SEQUENTIAL STARTUP

Yes

DATA LOGGING

Yes

Yes

No

DATA LOGGING

Yes

REMOTE PLAYER RESTART (WHEN PC IS ON)

Yes

Yes

Yes

REMOTE PLAYER RESTART (WHEN PC IS ON)

REMOTE PLAYER ON/OFF OR RESTART

Yes

Yes

No

REMOTE PLAYER ON/OFF OR RESTART